Hurricane Protection

Crimsafe® can protect your home against hurricane damage, while still letting light in and allowing you to view the outdoors. It is tested to withstand winds up to 200 MPH/322KPH, and missile impact up to 150 MPH/241KPH. And, unlike storm panels, Crimsafe is installed in place. There is no need to spend tense moments just before a storm climbing up on ladders and hammering boards into place.

HOW CRIMSAFE PROTECTS FROM IMPACT

At impact the hooking feature of the patented screw-clampTM (which runs along every edge of the product) levers into the aluminium frame and spreads the load right around the perimeter of the product, rather than allowing the force to be concentrated at the point of impact. The mechanical fastening of the clamp to the mesh also resists the tendency of the mesh to be pulled out of the frame. These features permit Crimsafe® to withstand enormous force.

Florida Building Code Approval Number : FL13259

Crimsafe Products tested and Design Pressures

Safe-S-Cape:
ATI report #92587.01-401-18
Size tested:
55" wide by 85" high (4' 7" x 7' 1")
Design Pressure:
±75.0 psf, structural overload ±112.5 psf / Porosity DP±99.0 psf
Florida Building Code:
FL13259
Miami Dade County NOA:
NOA 09-1005.03
Fixed Build-Out:
ATI report #98897.01-401-18
Size tested:
53" wide by 85" high (4' 5" x 7' 1")
Design Pressure:
±75.0 psf, structural overload ±112.5 psf / Porosity DP±99.0 psf
Florida Building Code:
FL#13779
Miami Dade County NOA:
NOA 10-0504.04
Patio Enclosure:
ATI report #98899.01-401-18
Size tested:
187" wide by 144" high (15' 7" x 12')
Single Panel Size:
61" wide by 96" high (5' 1" x 8' 0-3/8")
Design Pressure:
±50.0 psf, structural overload ±75.0 psf / Porosity DP±70.0 psf
Florida Building Code:
FL#13770
Miami Dade County NOA:
NOA 10-0706.04

Note: 2" x 6" X 1/4" vertical mullions, 2" x 1" X 1/8" horizontal mullions. One side was not secured for unlimited length. A single specimen was tested with horizontal midrail.

Hinge Door with top and bottom patio bolts for hurricane areas: ATI report #98889.01-401-18

Size tested:
42" wide by 81" high (3' 6" x 6' 9") /42" wide by 96" high (3' 6" x 8' 0")
Design Pressure:
±50.0 psf, structural overload ±75.0 psf / Porosity DP±63.5 psf
Florida Building Code:
FL#13771
Miami Dade County NOA:
NOA 10-0706.05

Note: 1 unit tested with a midrail, 4 units tested with full screen